• facebook
  • youtube
  • linkedin
Leave Your Message
Laboratory Equipment Textile Machinery Benchtop Spectrophotometer D36DS
Colorimeter
Products Categories
Featured Products

Laboratory Equipment Textile Machinery Benchtop Spectrophotometer D36DS

Design of dual optical path based on differential spectroscopy engine and 1nm grating
Automatic calibration technology to ensure long-term consistency of fluorescence measurements
Ultra-high accuracy and excellent inter-Instrument agreement guaranteed

    Overview

    Design of dual optical path based on differential spectroscopy engine and 1nm grating
    Automatic calibration technology to ensure long-term consistency of fluorescence measurements
    Ultra-high accuracy and excellent inter-Instrument agreement guaranteed


    Features

    Repeatability 0.01,Inter-Instrument Agreement 0.15
    1.Equipped with two types of lighting sources: pulse xenon lamp and LED
    2.37 standard light sources, 40+measurement indicators
    3.Automatic recognition of four apertures switching
    4.Temperature and humidity calculation compensation function
    4.7-inch touch screen, Android operating system
    5.Provide powerful ColorExpert computer data management software
    6.Can save data to the cloud and follow the account to prevent loss
    7.Support PC end export or printing of data test reports
    8.Support color matching software to provide more formula inspiration and improve color matching efficiency
    9.Differential spectrum engine improves overall measurement performance
    The light input of the sensor is increased by 50%, the spectral resolution is increased by 30%, the signal-to-noise ratio is higher, the repeatability, the difference between the instrument, and the data is highly consistent with the data of the standard instrument, the inter-instrument agreement can reach to 0.08, and the repeatability can reach to 0.005. The relevant technologies are protected by Chinese invention patents.
    10.Double optical path design improves repeatability accuracy Repeatability accuracy dE*ab≤0.01
    The dual optical path design monitors the energy fluctuation of the light source while measuring the sample signal, reduces interference during measurement, obtains higher measurement stability, and improves the measurement repeatability index of the instrument to dE*ab≤0.01. The high standard of measurement speed, accuracy, stability and inter-station difference is guaranteed. The relevant technologies are protected by Chinese invention patents and American invention patents.
    11.Innovative 1nm resolution grating spectroscopy technology
    Innovation is the soul of CHNSpec. After nearly 10 years of dedicated research, the grating combined array sensor made by the innovative MEMS process makes the color measurement more accurate on the basis of 1nm spectral resolution, once again leading the industry innovation direction and greatly improving the technical performance of the product. The relevant technologies are protected by Chinese invention patents.
    12.Excellent inter-instrument agreement:dE*ab≤0.15,
    13.High repeatability accuracy:dE*ab≤0.01,ensure accurate data transfer between factories
    14.Self-developed fluorescence calibration technique
    Automatically adjust the UV intensity, and ensure that the instrument value is highly consistent with the reference value when measuring the fluorescent material.
    15.High precision automatic calibration
    Advanced automatic calibration technology greatly improves long-term repeatability of instruments. Under constant temperature, the dE*ab of day 1 and day 30 can still reach 0.01. At any temperature change from 0℃ to 40℃, dE*ab can reach less than 0.1.
    Long-term repeatability curve at constant temperature   Repeatability curve of temperature change from 0 ℃ to 40 ℃
    16.Easily measure samples of many shapes with a variety of measuring apertures
    Four test calibers, free to switch
    Support measurement in reflection mode: solid, powder, non-transparent liquid
    Support measurement in transmission mode: glass, film, transparent liquid
    17.Configure high-definition preview camera
    The clarity of the camera has been significantly upgraded, from the original 400dpi to 1400dpi. When observing the sample, the clarity has been improved by 350% and brightness calibration algorithm has been used to truly restore the color of the ultra dark sample.
    18.Support for simultaneously saving sample data and images
    Recording image information while measuring data
    Obtain more sample related information


    Application

    企业微信截图_17684460201976

    Film

    企业微信截图_1763711376153

    Textile

    企业微信截图_17637115027535

    Fabrics

    Standards

    Standards

    Key Specifications

    Model

    D36DS

    Lighting/measuring conditions

    Reflection: d/8 (diffuse illumination, 8° direction reception)

    SCI(Contains specular reflected light)/ SCE(not contain specular reflected light)

    measure at same time. Compliance standards: CIE No.15, GB/T 3978, GB 2893,

    GB/T 18833, ISO7724/1, DIN5033 Teil7, JIS Z8722 Condition C, ASTM E1164, ASTM-D1003-07

    Transmission: d/0 (diffuse illumination, vertical reception)

    Sensor

    Differential spectrum engine

    Spectroscopic method

    Concave grating

    Integrating sphere diameter

    152mm

    Wavelength range

    360nm-780nm

    Wavelength interval

    10nm

    Half-wave width

    1.6nm

    Reflectance measurement range

    0-200%,resolution0.01%

    Lighting source

    Pulsed xenon lamps and LED

    Ultraviolet measurement

    Includes UV, 400nm cutoff, 420nm cutoff, 460nm cutoff

    Measuring time

    Single mode <2s

    Lighting/measuring calibers

    Reflection: XLAV Φ25.4mm/Φ30mm;LAVΦ15mm/Φ18mm;MAVΦ8mm/Φ11mm;

    SAVΦ3mm/Φ6mm Users can customize the calibre, and the calibre switch is automatically

    recognized Transmission:Φ17mm/Φ25mm

    Transmission measurement specification

    Sample height and thickness: height is not limited, thickness ≤50mm

    Long-term repeatability

    XLAV chroma value: standard deviation ΔE*ab within 0.1 (0℃-40℃ arbitrary temperature change)

    XLAV chroma value: standard deviation ΔE*ab 0.01 or less (under constant temperature conditions,

    the white correction plate is measured every hour within 24 hours)

    Repeatability *

    ΔE*ab≤0.01,

    Spectral reflection/transmittance ≤0.1%

    Inter-Instrument Agreement**

    XLAV ΔE*ab 0.15

    Standard observer

    2° and 10°

    Viewing light source

    A,B,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,U35,

    DLF,NBF,TL83,TL84,ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2

    Language

    Simplified Chinese, English, Traditional Chinese, Russian, Spanish, Portuguese,

    Japanese, Thai, Korean, German, French, Polish

    Display content

    Spectral data, Spectrogram, chromaticity data, chromaticity Data,

    chromaticity map, Pass/Fail judgment, Simulation color, Color evaluation, fog, liquid chromaticity, Color bias

    Color space

    CIE LAB,CIE LUV,LCh,Hunter Lab,Yxy,XYZ,Musell,s-RGB,βxy

    Chroma index

    WI(ASTM E313-20,ASTM E313-73,CIE,ISO2470/R457,AATCC,Hunter,Taube,Berger Stensby),

    YI(ASTM D1925,ASTM E313-20,ASTM E313-73),Tint(ASTM E313-20),Isochromatic index Milm,

    color fastness, color changing fastness,ISO brightness,R457,A density,T density,E density,M density,

    APHA/Hazen/Pt-Co(platinum-cobalt index),Gardner(Gardner Index),Saybolt(Seibert Index),Astm color,

    fog, total transmittance, covering power, force, intensity

    Color difference formula

    ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc,ΔE*94,ΔE*00,ΔEab(Hunter),555 color tone classification

    Storage

    8GB

    Screen size

    7-inch capacitive touch screen

    Audit Trail

    Yes (according to FDA and CFDA requirements)

    Operating system

    Android

    Power sourc

     

    Product Details

    P1044629

    Aperture plate

    P1044657 - 副本

    Control panel

    Production Processes

    图片1

    Process design and design and manufacture of specialized process equipment

    image0316kf

    Machining of components

    Assembly of products

    Assembly of products

    image0267we

    Comprehensive testing of machines

    Scenarios of Use

    image030cct

    Laboratory

    image027i5g

    Textile factory

    Operation

    1

    Connecting the air supply

    Connect the air supply to the instrument.
    2

    Add distilled water

    Connect tube from the freestanding funnel to the water connector located at the back right-hand corner of the SST unit. Add distilled water.
    3

    Put in filte

    Unscrew the screws and remove the top plate,Take away the reflector.
    Put in filter.
    4

    Install the xenon lamp

    Install the xenon lamp and connect the lamp cabler.Replace the top cover and tighten the set screws.
    5

    Mount the sample

    Mount the sample on the sample clamp.
    6

    BPT Sampling

    Place the sample into the test chamber and close the door.Be careful to avoid covering the BPT sensor.

    Transportation

    image071evh

    Packing System

    1. Products are covered with air bubble film before put them into composite board standard export wooden case. To ensure waterproof, moistureproof, corrosion, anti-corrosion and security.
    2. Package with shipping mark in line with International and national standards, which is easy for handling, loading and unloading.
    3. Packing materials selected accorded with economic and safety requirements
    4. Compliance with environmental requirements.

    For Metal Box Package

    image07470y
    image075gi2
    图片1

    For Carton Package

    image078n3e
    image07703l
    image079bsv

    For Wooden Case

    image081602
    image082szo
    image0800r6